CNTEV=BOTH, AUXCNTEV=NONE, MODE=DISABLE
Control Register
MODE | Mode Select 0 (DISABLE): The module is disabled. 1 (OVSSINGLE): Single input LFACLK oversampling mode (available in EM0-EM2). 2 (EXTCLKSINGLE): Externally clocked single input counter mode (available in EM0-EM3). 3 (EXTCLKQUAD): Externally clocked quadrature decoder mode (available in EM0-EM3). |
CNTDIR | Non-Quadrature Mode Counter Direction Control |
EDGE | Edge Select |
FILT | Enable Digital Pulse Width Filter |
RSTEN | Enable PCNT Clock Domain Reset |
HYST | Enable Hysteresis |
S1CDIR | Count direction determined by S1 |
CNTEV | Controls when the counter counts 0 (BOTH): Counts up on up-count and down on down-count events. 1 (UP): Only counts up on up-count events. 2 (DOWN): Only counts down on down-count events. 3 (NONE): Never counts. |
AUXCNTEV | Controls when the auxiliary counter counts 0 (NONE): Never counts. 1 (UP): Counts up on up-count events. 2 (DOWN): Counts up on down-count events. 3 (BOTH): Counts up on both up-count and down-count events. |